نمایش گردوخاک DT450G

تماس بگیرید

توضیحات

Measurement objectsSolid particles in gas

Particle size: 0.3 μm or greater

Measurement range۰٫۱ mg/m3 to 1 kg/m3
Measurement principleInductive electrification
Sample gas conditionsTemperature :250℃ or less

Pressure: 200 kPa or less

Gas flow rate: 4 m/s or greater (approx. 30 m/s Max.)

Humidity: 40 %RH or less

Setting measurement rangeRange setup: One-touch automatic setup or manual setup Note: With one-touch automatic setup function, measurement range is set so that the dust concentration of the process corresponds to a setpoint of setting level. In manual setup, the measurement range is set by gain (x1, x10, x100, x1000, x10000). Setup range: Variable (10 to 50%, 10% step)
Analog output signal۴ to 20 mA DC (isolated, load resistance of 500 Ω)
Contact output signal (high/low alarm)۲ outputs
Ambient conditionsTemperature: -20 to 45℃

Humidity: 95% RH or less (non-condensing)

Vibration: 5 m/S2 (0.5G) or less

ConstructionIntegrated sensor and converter Direct insertion type, rainproof (IP64)
MaterialsSensor probe: Stainless steel (316SS equivalent)

Insulation of sensor: PEEK

Case: Aluminum

Power supply۱۰۰-۱۲۰ V AC or 200-240 V AC, 50/60 Hz, 8VA
Air purgeInstrument air (dry air) Pressure: +50 kPa or greater (continuous)

Air Connection: Rc 1/4

Air consumption; Approx. 50 Nl/min

WeightApprox. 2.3 kg (excluding flange)
Dimensions۱۷۲(W) x 173(H) x 672(D) mm

توضیحات تکمیلی

وزن2300 گرم
ابعاد680 × 180 × 180 میلی‌متر

دانلودها

Brochures
Instruction Manuals
General Specifications

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

.فقط مشتریانی که این محصول را خریداری کرده اند و وارد سیستم شده اند میتوانند برای این محصول دیدگاه(نظر) ارسال کنند.